n Attach the Flood Detector (applicable for both parts) to a surface that is clean, dry, flat and smooth.
n The Flood Detector must be mounted within 700m (2300ft) (open air nominal) of the CCU.
n Typically, the Transmitter Unit will be attached onto a nearby wall or furniture while the Sensor Unit is
built for installation directly onto the potentially flooded zone.
3.11.2.2 Installing the Flood Detector Transmitter Unit with Screws
1. Release the Flood Detector Transmitter Unit base by inserting a coin into one of the edge slots, as
demonstrated in the Figure 117 above, and twist it to open the cover.
2. Use a flat screwdriver to remove the punch-outs 1 and 2 (see Figure 118 below).
Figure 118: Flood Detector Transmitter Unit Base with Screws
3. Place and hold the base on the desired mounting location and mark the drilling locations (the above-
mentioned punch-outs 1 and 2).
4. Drill the holes; insert two (2) dowels if needed, place the base over them and screw in the two (2) screws.
5. Attach the Transmitter Unit onto its base.